Zurück

HI 93703C Turbidimeter ISO 7027 with Calibration Standard & Casing

Manufacturer: HANNA Instruments Inc.

Order number: HI93703C

Availability:         3 pcs. in stock
 

Ready to ship today,
Delivery time appr. 1-3 workdays

3,126.00AED *
 
 
 
 
 

Product information "HI 93703C Turbidimeter ISO 7027 with Calibration Standard & Casing"

  • GLP Features
  • 3 point calibration

 

HI 93703 series are microprocessor based turbidity meters that provide laboratory accuracy for field turbidity measurements.

The HI 93703 is easy to calibrate (with 3 point calibration) using AMCO-EPA standards and is ISO 7027 compliant.

HANNA instruments has chosen 10 FTU* as the calibration point because it is the value that best fits the water turbidity measurements in different applications, from drinking water to wastewater treatment. HANNA instruments uses the primary standard AMCO-AEPA-1 to avoid all formazine-related problems. Formazine is a very toxic, unstable substance which requires particular care: its standards have to be prepared only a few minutes before performing the calibration, and cannot be reused because of their short life. HANNA AMCO-AEPA-1 standards are extremely stable, can be reused, and last up to six months if free from contamination. HI 93703 can be used with both standards.

It meets the requirements of GLP (Good Laboratory Practice) protocols for last calibration data storage.

*FTU is equivalent to the other internationally recognized unit NTU (Nephelometric Turbidity Unit. 

Order Information: HI 93703C, kit including HI 93703 and HI 731313 maintenance kit.

Product Manuals

  Manual: Download

Specification :

Range   0.00 to 50.00 FTU; 50 to 1000 FTU
Resolution   0.01 FTU (0.00 to 50.00 FTU); 1 FTU (50 to 1000 FTU)
Accuracy   ±0.5 FTU or ±5% of reading (whichever is greater)
Calibration   3 points (0 FTU, 10 FTU and 500 FTU)
Light Source   infrared LED
Light Detection   Silicon Photocell
Battery Type / Life   1.5V AA (4) /approximately 60 hours of continuous use or 900 measurements;  auto-off after 5 minutes of non-use
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions   220 x 82 x 66 mm (8.7 x 3.2 x 2.6")
Weight   510 g (1.1 lb.)

 

 