HI 8710 pH Analog Controller with Self-Diagnostic Test

Manufacturer: HANNA Instruments Inc.

Order number: HI8710

Availability:         0 pcs. in stock
 

Delivery time approx. 2 to 4 weeks

1,951.00AED *
 
 
 
 
 

Product information "HI 8710 pH Analog Controller with Self-Diagnostic Test"

 

  • Inputs: BNC connector,  Direct wire connection with amplified probe (supports HI 1006 series probes) and 4-20 mA from a transmitter
  • Extended temperature compensation  range: -20 to 100°C
  • Supports potential matching pin connection
  • Both 4-20 and 0-20 mA output
  • ±5V outputs for amplified electrodes
  • Backlit LCD
  • Auto-diagnostic tests for pH electrode and instrument status
  • Operational mode LED indicators
  • Fail Safe Function–the alarm relay is activated at power down
  • Transparent splash-proof cover

 

HI 8710 is a panel mounted pH controller with self-diagnostic test capabilities. Users can set: the setpoint for acid or alkaline dosage, the tolerance of the setpoint before an alarm is activated, the dosage mode: automatic, continuous on or OFF and the over dosage control by setting the overtime dosage knob.

When used in conjunction with the HI 8720 ORP controller, the ODCD* function will ensure that the ORP dosage will start only when the pH level is correct.

“Overtime dosage” function with selection knob and jumper for disable on the rear panel. If the dosing relay remains continuously activated for more than selected dosing time the alarm relay is activated, the alarm LED is blinking and the dosing relay is deactivated.

* ORP dosing consent device

 

Order Information:
The HI 8710 is supplied complete with mounting brackets and instructions.

  • Specifications
  • Accessories
  • Downloads
Range   0.00 to 14.00 pH
Resolution   0.01 pH
Accuracy
@ 20 °C
  ±0.02 pH (0 to 100 °C)
±0.05 pH (-20 to 0 °C)
±0.5% (input from transmitter)
Input   high impedance 1012 Ohm; reference and matching pin inputs are available; 4-20 mA
Power Output   ±5 Vcc; 150 mA max load for amplified electrodes
Calibration   offset: ±2 pH with OFFSET trimmer
slope: 80 to 110% with SLOPE trimmer
Temperature
Compensation
  fixed or automatic with Pt100, from -20 to 100°C (-4 to 212°F)
Recorder Output   0-20 mA or 4-20 mA (isolated)
Setpoint Relay   1, isolated, 2 A, max 240 V, resistive load, 1000000 strokes (not fuse protected)
Setpoint Range   0.00 to 14.00 pH
Alarm Relay   1, isolated, 2 A, max 240 V, resistive load, 1000000 strokes (not fuse protected)
Alarm Range   0.2 to 3.00 pH
Consent Relay   1, isolated, 2 A, max 240 V, resistive load, 1000000 strokes (not fuse protected)
Dosing Control   OFF/AUTO/ON with selection switch
Over Dosing Control   adjustable, from 5 min to 60 min with knob or disable by wire strap - on rear panel
Backlight   continuous on
Power Supply   115 VAC ±10% or 230 VAC ±10%; 50/60 Hz
Enclosure   flame retardant ABS body and front panel; transparent splash-proof front cover
Environment   -10 to 50°C (14 to 122°F); RH max 95% non-condensing
Panel Cutout   141 x 69 mm (5.6 x 2.7")
Weight   1 kg (2.2 lb.)
Solutions
HI 7004/1L 4.01 pH Buffer Solution
1 x 1 L bottle
HI 7007/1L 7.01 pH Buffer Solution
1 x 1 L bottle
HI 7010/1L 10.01 pH Buffer Solution
1 x 1 L bottle
Accessories
HI 8427 pH and mV Precision Simulator
HI 931001 pH and mV Precision Simulator
Product Manuals

  Manual: Download

 

Onward links to "HI 8710 pH Analog Controller with Self-Diagnostic Test"

Further products by HANNA Instruments Inc.
 

Customer evaluation "HI 8710 pH Analog Controller with Self-Diagnostic Test"

 
Evaluations will be activated after verification

Write an evaluation

 
 
 
 
 
 
 

The fields marked with * are required.