HI 96718 Iodine Portable Photometer

Manufacturer: HANNA Instruments Inc.

Order number: HI96718

Availability:         0 pcs. in stock

Delivery time approx. 2 to 4 weeks

828.00AED *

Product information "HI 96718 Iodine Portable Photometer"

  • User calibration
  • Certified calibration and verification standards
  • BEPS (Battery Error Prevention System)
  • TIMER function
  • Auto shut-off
  • GLP Features


The disinfectant properties of Iodine have led to its use as an alternative to chlorine and bromine. Unlike chlorinated pools, water treated with iodine decreases eye irritation among swimmers, and provides a level of disinfection more stable to adverse conditions.
However, its toxic and corrosive properties and the difficulties of dissolving it in water has limited it’s widespread acceptance. One of its most common applications is in poultry industry process water.

HI 96718 uses an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit a cuvette with a larger neck making it easier to add both sample and reagents. The cuvette is made from special optical glass to obtain best results.

The HI 96718 measures the Iodine content in water samples in the 0.0 to 12.5 mg/L (ppm) range. The method is an adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method.



Order Information:
HI 96718 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual. 
HI 96718C includes HI 96718 photometer, sample cuvettes with caps (2 ea.), 9V battery, scissors, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.

  • Specifications
  • Accessories
  • Downloads
Range 0.0 to 12.5 mg/L
Resolution 0.1 mg/L
Accuracy ±0.1 mg/L ±5% of reading @ 25°C
Light Source Tungsten lamp
Light Detector Silicon photocell with narrow band interference filter @ 525 nm
Method adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method
Environment 0 to 50°C (32 to 122°F); max 95% RH non-condensing
Power Supply 9V battery
Auto-Shut off after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Dimensions 192 x 104 x 69 mm (7.6 x 4.1 x 2.7")
Weight 360 g (12.7 oz.)
Product Manuals

  Manual: Download

HI 93703-50Cuvette Cleaning Solution
HI 731331Glass Cuvette Set
HI 731335Cuvette Cap for HI 957xx Series Meters
Reagents & Standards
HI 96718-11CAL CHECK™ standard cuvettes (I2)
HI 93718-01Iodine, DPD Method (100 Tests)
HI 93718-03Iodine, DPD Method (300 Tests)

Onward links to "HI 96718 Iodine Portable Photometer"

Further products by HANNA Instruments Inc.

Customer evaluation "HI 96718 Iodine Portable Photometer"

Evaluations will be activated after verification

Write an evaluation


The fields marked with * are required.