Product information "HI 83205-02 Multiparameter Photometer for Boilers and Cooling Towers"

  • Light blocking cuvette holder
  • Backlit LCD
  • BEPS (Battery Error Prevention System) Alerts users in the event a low battery could effect readings
  • PC compatible via USB
  • Powered by rechargeable batteries or 12 VDC
  • Save and recall logged data at the touch of a button.
  • On-screen tutorial; with the tutorial function enabled, short guides relating to current operation are displayed.
  • HELP button; screen specific help can viewed at the touch of a button.
  • Method selection; users can easily select parameters via the Method button.
  • Setup button; instrument preferences such as backlight intensity and screen contrast can be changed via the setup button.

 

HI 83205 is a multiparameter bench meter that measures twenty-four methods essential for monitoring boiling and cooling towers.  It has four channels allowing for a wide range of tests.

With just one unit, technicians can keep an eye on 24 methods needed for proper and efficient functioning of their systems. The parameters that HI?83205 monitors include: iron, whose presence can be an important indication of corrosion; chlorine to circumvent microbiological fouling; dissolved oxygen, whose presence causes corrosion; silica can point to a contamination of the feed water while phosphate is important to reduce scaling.

The optical system of HI 83205 is based on special subminiature tungsten lamps and narrow-band interference filters to guarantee both high performance and reliable results.

HI 83205 has a powerful interactive user support that assists the user during the analysis process. A full tutorial is available in the Setup Menu, and the Help Menu provides assistance for every step in the measurement process. This meter can be connected to a PC via a USB cable, where the data can be managed with optional HI 92000 Windows® compatible software.

 

Order Information:
HI 83205-01 (115V) and HI 83205-02 (230V) are supplied sample cuvettes and caps (2 ea.), cloth for wiping cuvettes, 60 mL glass bottle for dissolved oxygen analysis, scissors, AC/DC power adapter, and instruction manual.

Product Manuals

  Manual: Download

Light Source up to 5 tungsten lamps with different narrow band interference filters
Light Detector silicon photocell
Environment 0 to 50°C (32 to 122°F); max 90% RH non-condensing
Power Supply external 12 VDC power adapter or built-in rechargeable battery
Dimensions 235 x 200 x 110 mm (9.2 x 7.87 x 4.33")
Weight 0.9 Kg (2 lbs.)
Multi Parameter Specifications
ParameterRangeMethodReagent Code
Aluminum0.00 to 1.00 mg/L (ppm)AluminonHI 93712-01
Ammonia LR0.00 to 3.00 mg/L (ppm)NesslerHI 93700-01
Ammonia MR0.00 to 10.00 mg/L (ppm)NesslerHI 93715-01
Bromine0.00 to 8.00 mg/L (ppm)DPDHI 93716-01
Chlorine Dioxide0.00 to 2.00 mg/L (ppm)Chlorophenol RedHI 93738-01
Chlorine, Free0.00 to 2.50 mg/L (ppm)DPDHI 93701-01
Chlorine, Total0.00 to 3.50 mg/L (ppm)DPDHI 93711-01
Chromium VI HR0 to 1000 µg/LDiphenyl-
carbohydrazide
HI 93723-01
Chromium VI LR0 to 300 µg/LDiphenyl-
carbohydrazide
HI 93749-01
Copper HR0.00 to 5.00 mg/L (ppm)BicinchoninateHI 93702-01
Copper LR0 to 1000 µg/LBicinchoninateHI 95747-01
Hydrazine0 to 400 µg/Lp-Dimethyl-
aminobenzaldehyde
HI 93704-01
Iron HR0.00 to 5.00 mg/L (ppm)PhenantrolineHI 93721-01
Iron LR0 to 400 µg/LTPTZHI 93746-01
Molybdenum0.0 to 40.0 mg/L (ppm)Mercaptoacetic AcidHI 93730-01
Nitrate0.0 to 30.0 mg/L (ppm)Cadmium ReductionHI 93728-01
Nitrite HR0 to 150 mg/L (ppm)Ferrous SulfateHI 93708-01
Nitrite LR0.00 to 0.35 mg/L (ppm)DiazotizationHI 93707-01
Oxygen,
Dissolved (DO)
0.0 to 10.0 mg/L (ppm)WinklerHI 93732-01
pH6.5 to 8.5 pHPhenol redHI 93710-01
Phosphate HR0.0 to 30.0 mg/L (ppm)Amino AcidHI 93717-01
Phosphate LR0.00 to 2.50 mg/L (ppm)Ascorbic AcidHI 93713-01
Silica0.00 to 2.00 mg/L (ppm)Heteropoly blueHI 93705-01
Zinc0.00 to 3.00 mg/L (ppm)ZinconHI 93731-01
Solutions
HI 93703-50Cuvette Cleaning Solution
Accessories
HI 93703-55Active Carbon
HI 731318Cuvette Cleaning Cloth
HI 731321Glass Cuvette Set
HI 731325WCap Set for Glass Cuvettes
HI 740036PPlastic Beaker Set, 100 mL
HI 740143Graduated Syringe Set (6), 1 mL
HI 740220Glass Cylinder Set, 25 mL
HI 740225Syringe, 60 mL
HI 740226Graduated Syringe, 5 mL
HI 740227Filter Assembly
HI 740228Filter Set (25)
HI 740230Demineralized Bottle, 230 mL
HI 92000Windows® Compatible Software
HI 920013USB Cable
HI 93702-01Copper HR, bicichoninate acid method (100 Tests)
Reagents & Standards
HI 93702-03Copper HR, bicichoninate acid method (300 Tests)
HI 95747-01Copper, LR, Bicinchoninate Acid Method (100 Tests)
HI 95747-03Copper, LR, Bicinchoninate Acid Method (300 Tests)
HI 93704-01Hydrazine (100 Tests)
HI 93704-03Hydrazine (300 Tests)
HI 93721-01Iron HR, Phenanthroline Method (100 Tests)
HI 93721-03Iron HR, Phenanthroline Method (300 Tests)
HI 93746-01Iron LR, TPTZ Method (100 Tests)
HI 93746-03Iron LR, TPTZ Method (300 Tests)
HI 93730-01Molybdenum, Mercaptoacetic Method (100 Tests)
HI 93730-03Molybdenum, Mercaptoacetic Method (300 Tests)
HI 93728-01Nitrate, Cadmium Reduction Method (100 Tests)
HI 93728-03Nitrate, Cadmium Reduction Method (300 Tests)
HI 93708-01Nitrite HR, ferrous sulphate method (100 Tests)
HI 93708-03Nitrite HR, ferrous sulphate method (300 Tests)
HI 93707-01
Nitrite LR, diazotization method (100 Tests)
HI 93707-03Nitrite LR, diazotization method (300 Tests)
HI 93732-01Dissolved Oxygen, Winkler Method
HI 93732-03Reagents for 300 tests (DO)
HI 93710-01pH, Phenol Red Method (100 Tests)
HI 93710-03pH, Phenol Red Method (300 Tests)
HI 93717-01Phosphate HR, Amino Acid Method (100 Tests)
HI 93717-03Phosphate HR, Amino Acid Method (300 Tests)
HI 93713-01Phosphate LR, Ascorbic Acid Method (100 Tests)
HI 93713-03Phosphate LR, Ascorbic Acid Method (300 Tests)
HI 93705-01Silica (100 Tests)
HI 93705-03Silica (300 Tests)
HI 93731-01Zinc, Zincon Method (100 Tests)
HI 93731-03Zinc, Zincon Method (300 Tests)
HI 93712-01Aluminium, Aluminon Method (100 Tests)
HI 93712-03Aluminium, Aluminon Method (300 Tests)
HI 93715-01Ammonia MR, Nessler Method (100 Tests)
HI 93715-03Ammonia MR, Nessler Method (300 Tests)
HI 93700-01Ammonia LR, Nessler Method (100 Tests)
HI 93700-03Ammonia LR, Nessler Method (300 Tests)
HI 93716-01Bromine, DPD Method (100 Tests)
HI 93716-03Bromine, DPD Method (300 Tests)
HI 93738-01Chlorine Dioxide, Chlorophenol Red Method (100 Tests)
HI 93738-03Chlorine Dioxide, Chlorophenol Red Method (300 Tests)
HI 93701-01Chlorine, free, DPD Method (100 Tests)
HI 93701-03Chlorine, free, DPD Method (300 Tests)
HI 93711-01Chlorine, Total, DPD Method (100 Tests)
HI 93711-03Chlorine, Total, DPD Method (300 Tests)
HI 93723-01Chromium VI HR, Diphenylcarbohydrazide Method (100 Tests)
HI 93723-03Chromium VI HR, Diphenylcarbohydrazide Method (300 Tests)
HI 93749-01Chromium VI LR, Diphenylcarbohydrazide Method (100 Tests)
HI 93749-03Chromium VI LR, Diphenylcarbohydrazide Method (300 Tests)
 

Onward links to "HI 83205-02 Multiparameter Photometer for Boilers and Cooling Towers"

Further products by HANNA Instruments Inc.
 

Customer evaluation "HI 83205-02 Multiparameter Photometer for Boilers and Cooling Towers"

 
Evaluations will be activated after verification

Write an evaluation

 
 
 
 
 
 
 

The fields marked with * are required.