Zurück
Vor

HI 96752 Calcium and Magnesium Portable Photometer

Manufacturer: HANNA Instruments Inc.

Order number: HI96752

Availability:         3 pcs. in stock
 

Ready to ship today,
Delivery time appr. 1-3 workdays

885.00AED *
 
 
 
 
 

Product information "HI 96752 Calcium and Magnesium Portable Photometer"

  • CAL CHECK™
  • User calibration
  • Certified calibration and verification standards
  • BEPS (Battery Error Prevention System)
  • TIMER function
  • Auto shut-off
  • GLP Features
     

 

The HI 96752 measures two important parameters in agricultural and hydroponic applications.

HI 96752 measures calcium concentrations from 0 to 400 mg/L and magnesium from 0 to 150 mg/L and the values are displayed directly on the large LCD to eliminate the need for conversion tables.

This handy and portable meter with a low cost-per-test is an ideal hi-tech alternative to chemical test kits.

Accurate and cost-saving, this two in one portable photometer is factory calibrated to measure only calcium and magnesium, to provide an instrument that is easy to use in the lab or on the field.

 

 

Order Information:
HI 96752 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.

  • Specifications
  • Accessories
  • Downloads
RangeCalcium0 to 400 mg/L (ppm)
 Magnesium0 to 150 mg/L (ppm)
ResolutionCalcium1 mg/L (ppm)
 Magnesium1 mg/L (ppm)
Accuracy @25°CCalcium±10 mg/L ±5% of reading
 Magnesium±3 mg/L ±3% of reading
Light Source light emitting diode
Light Detector silicon photocell with narrow band interference filter @ 466 nm
Power Supply 9V Battery
Auto-off after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 192 x 104 x 69 mm (7.6 x 4.1 x 2.7")
Weight 360 g (12.7 oz.)
MethodCalciumadaptation of Oxalate method
 Magnesiumadaptation of the Calmagite method


Product Manuals

  Manual: Download

Solutions
HI 93703-50Cuvette Cleaning Solution
Accessories
HI 731318Cuvette Cleaning Cloth
HI 731331Glass Cuvette Set
HI 731335Cuvette Cap for HI 957xx Series Meters
Reagents & Standards
HI 93752-01Calcium and Magnesium HR, Oxalate (Ca) and Calmagite (Mg) (100 Tests)
HI 93752-03Calcium and Magnesium HR, Oxalate (Ca) and Calmagite (Mg) (300 Tests)
 

Onward links to "HI 96752 Calcium and Magnesium Portable Photometer"

Further products by HANNA Instruments Inc.
 

Customer evaluation "HI 96752 Calcium and Magnesium Portable Photometer"

 
Evaluations will be activated after verification

Write an evaluation

 
 
 
 
 
 
 

The fields marked with * are required.